Reactive Dyes — Recommended Application Processes
Reactive Dyes — Recommended Application Processes
Introduction
Reactive dyes are the standard choice for dyeing cellulosic fibres — cotton, viscose, linen and their blends — because the dye forms a covalent bond with the fibre and delivers bright shades with good wet-fastness once unfixed dye is properly washed off. Getting that bond to form efficiently, however, depends on choosing the right application process and holding the right alkali, salt, temperature and time conditions.
This guide sets out the four application processes we recommend for FNAT reactive dyes, with the chemical dosages and process parameters for each. All figures are taken from our application recommendation sheet. Where a parameter depends on depth of shade, it is given as a dosage band rather than a single number.
1. Exhaustion (batch) dyeing
Exhaustion dyeing is the most versatile route and suits dyehouses of any size, particularly for small-to-medium lot sizes and wide shade ranges. Two temperature profiles are recommended.
1.1 Warm dyeing at 60 °C
For dyes of the warm-dyeing type:
- At room temperature, enter auxiliaries and fabric, run 10 min.
- Add dyestuff over 10–30 min, run 10 min.
- Add Glauber's salt over 10–30 min, run 5 min.
- Heat at 1 °C/min to 60 °C.
- At 60 °C run 10 min, then add soda ash over 20–40 min.
- Fix for 45–60 min at 60 °C.
1.2 Migration / warm dyeing at 80 / 60 °C
For dyes requiring a migration step to level the shade before fixation:
- At room temperature, enter auxiliaries and fabric, run 10 min.
- Add dyestuff over 10–30 min, run 10 min.
- Add Glauber's salt over 10–30 min, run 5 min.
- Heat at 1 °C/min to 80 °C and hold 20–30 min for migration.
- Cool at 1 °C/min (approx. 20 min) to 60 °C.
- Add soda ash and fix for 45–60 min at 60 °C.
1.3 Salt and alkali dosage (exhaustion)
Dosages below apply to non-mercerized cotton at a liquor ratio of 10:1.
| Dyestuff (% o.w.f.) | <0.5 | 0.5–1 | 1–2 | 2–3 | 3–5 | >5 |
|---|---|---|---|---|---|---|
| Glauber's salt (g/L) | 25 | 30 | 40 | 50 | 70 | 100 |
| Soda ash (g/L) | 5 | 8 | 12 | 15 | 20 | 20 |
1.4 Washing off after exhaustion dyeing
Residual unfixed dye, salt and alkali must be removed thoroughly; incomplete washing off is the most common cause of poor wet-fastness in reactive dyeing. Recommended sequence:
| Step | Operation | Temperature | Time |
|---|---|---|---|
| 1 | Cold rinsing | 40 °C | 10 min |
| 2 | Neutralizing (cold) | 40 °C | 10 min |
| 3 | Hot rinsing | 80 °C | 10 min |
| 4 | Soaping | 98 °C | 10 min |
| 5 | Warm rinsing | 60 °C | 10 min |
| 6 | Cold rinsing | 40 °C | 10 min |
For dark shades, a second soaping at 98 °C is recommended.
2. Cold-pad-batch (CPB) process
Cold-pad-batch is the lowest-energy continuous-to-semi-continuous route: fixation proceeds at ambient temperature over an extended batching period, which makes it well suited to knit goods and to mills without steam capacity for fixation.
Process sequence: padding → batching 8–12 hrs at 25 °C → washing off.
Pad liquor (20–25 °C):
| Component | Dosage |
|---|---|
| Reactive dye | X g/L (per shade) |
| Wetting agent | 2–4 g/L |
| Urea | 100 g/L, if necessary |
Alkali dosage (20–25 °C), by dye concentration in the pad liquor:
| Dyestuff (g/L) | 20 | 40 | 60 | 80 | 100 |
|---|---|---|---|---|---|
| Soda ash (g/L) | 30 | 30 | 30 | 30 | 30 |
| Caustic soda (g/L) | 3 | 4 | 5 | 6 | 8 |
Keep the pad liquor and the batching room at 20–25 °C: fixation kinetics in CPB are temperature-driven, and a cold batching room will leave the shade under-fixed.
3. Pad-dry-pad-steam process
Two-bath pad-dry-pad-steam is the recommended route for continuous dyeing of woven and knitted cellulose at medium to large lot sizes, where dye and fixation chemicals are applied in separate steps.
Process sequence: padding dye liquor → IR predrying → hot air 100–130 °C → padding chemicals → saturated steam 45–90 sec → washing off.
Dye liquor (pickup 50–70%):
| Component | Dosage |
|---|---|
| Reactive dye | X g/L (per shade) |
| Wetting agent | 2–4 g/L |
| Anti-migration agent | 5–10 g/L |
| Resist salt | 5–10 g/L |
Fixation chemicals (pickup 70–80%), by dye concentration:
| Dyestuff (g/L) | <20 | 20–30 | >30 |
|---|---|---|---|
| Common salt (g/L) | 250 | 250 | 250 |
| Soda ash (g/L) | 20 | 20 | 20 |
| Caustic soda (g/L) | 3 | 4 | 5 |
The anti-migration agent and resist salt in the dye liquor matter most during the drying stage: they hold the dye in place while water evaporates, preventing listing and side-to-side shade variation.
4. Pad-dry-thermofix process
Where saturated steam is not available, thermofixation offers a one-bath continuous alternative: dye and alkali are padded together, the fabric is dried, and fixation is completed in hot air.
Process sequence: padding (pickup 50–60%) → drying 110–130 °C → thermofix 140 °C, 60 sec → washing off.
Pad liquor composition, by dye concentration:
| Component | Dyestuff <10 g/L | 10–30 g/L | 30–60 g/L |
|---|---|---|---|
| Urea (g/L) | 20 | 20–50 | 50 |
| Wetting agent (g/L) | 2–5 | 2–5 | 2–5 |
| Anti-migration agent (g/L) | 10–20 | 10–20 | 10–20 |
| Soda ash (g/L) | 10 | 15 | 20 |